320 W Monocrystalline Module

The figures below refer to AXN6M610T320. Use the configuration table for other variants.

Nameplate DC power
320 W DC
Maximum-power voltage (DC)
33.4705 V DC
PTC power (DC)
294 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for AXN6M610T320
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
AXN6M610T320PV Module-Full row 694320 W DC294 W DCListed in CEC

Source specifications and conditions

Additional source information for AXN6M610T320. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Mounting
Rack
NOCT (°C)
46.67
Module type
Flat Plate
Long side (m)
1.64
Module family
Monocrystalline
Short side (m)
0.992
Cells in series
60
Module area (m²)
1.6268799999999999
PTC rating (W DC)
294
Safety certification
UL 1703
Parallel cell strings
1
Building-integrated PV
N
Maximum-power current Imp (A)
9.56066044393779
Short-circuit current Isc (A)
10.521439908861499
Open-circuit voltage Voc (V DC)
41.8410553777059
Maximum-power voltage Vmp (V DC)
33.470491068732095
Pmax temperature coefficient (%/°C)
-0.386

Documented compatibility

No specific equipment pairing has been verified for this model.