Equipment overview

525 W, 144 half-cut cell monocrystalline module, white backsheet, 1500V max system Vdc

The figures below refer to CHSM72M-HC-525. Use the configuration table for other variants.

Nameplate DC power
525 W DC
Maximum-power voltage (DC)
41.2605 V DC
PTC power (DC)
486 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for CHSM72M-HC-525
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
CHSM72M-HC-525PV Module-Full row 2120525 W DC486 W DCListed in CEC

Source specifications and conditions

Additional source information for CHSM72M-HC-525. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
45.52
Source notes
Formerly Chint Solar (Zhejiang) Co., Ltd.
Module family
Monocrystalline
Cells in series
72
CEC listing date
2021-08-23
Module area (m²)
2.48
PTC rating (W DC)
486
Source last update
2022-10-03
Safety certification
UL 61730
Parallel cell strings
2
Building-integrated PV
N
Maximum-power current Imp (A)
12.72403259
Short-circuit current Isc (A)
13.43
Open-circuit voltage Voc (V DC)
49.1
Maximum-power voltage Vmp (V DC)
41.2605042
Pmax temperature coefficient (%/°C)
-0.3829

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECCHSM72M-HC-525
    Archived CEC source