Chint Power Systems America

CPS ECB125KTL-M/US-480

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

Inverter with Additional Devices

The figures below refer to CPS ECB125KTL-M/US-480 {480V}. Use the configuration table for other variants.

Controlled apparent power
125 kVA
Operating voltage
480 V
PCS functionality
Inverter
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for CPS ECB125KTL-M/US-480
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
CPS ECB125KTL-M/US-480 {480V}PCS Data for Inverter and ESS row 29125 kVA480 VListed in CEC

Source specifications and conditions

Additional source information for CPS ECB125KTL-M/US-480 {480V}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Equipment type
Inverter
CEC listing date
2025-01-13
Export-only mode
Y
Import-only mode
Y
No-exchange mode
Y
Unrestricted mode
Y
Source last update
2025-06-23
Phase configuration
Multi
PCS CRD document date
2025-04-16
PCS CRD issuing entity
CSA Group
Additional required devices
External Meter: EG4030, CPS Local Controller: CPS C1000, and External CT: ACTL-0750-200
Output voltage as reported (V)
480
Export-only response time (seconds)
1.34
Import-only response time (seconds)
1.69
No-exchange response time (seconds)
1.62
Current measurement reference points
Inverter, External Meters and CTs
Unrestricted response time (seconds)
1.97
Maximum apparent power as reported (kVA)
125
Maximum continuous current as reported (A)
150

Documented compatibility

No specific equipment pairing has been verified for this model.