Chint Power Systems America

CPS-ESSR-ECH11.4US-60L1US

Energy storage · 2 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

11.4 kW, 60 kWh, energy storage system

The figures below refer to CPS-ESSR-ECH11.4US-60L1US {208V}. Use the configuration table for other variants.

Nameplate power
11.4 kW
Nominal AC voltage
208 V AC
Nameplate energy capacity
60 kWh
Technology
Lithium Ion
UL 1741 SB in CEC source
Reported
JA12 declaration
N

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for CPS-ESSR-ECH11.4US-60L1US
CEC model / configurationNameplate powerCapacityObservationCompare
CPS-ESSR-ECH11.4US-60L1US {208V}Energy Storage System row 57711.4 kW60 kWhListed in CEC
CPS-ESSR-ECH11.4US-60L1US {240V}Energy Storage System row 57811.4 kW60 kWhListed in CEC

Source specifications and conditions

Additional source information for CPS-ESSR-ECH11.4US-60L1US {208V}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

CEC listing date
2024-08-21
PV DC input capability
Y
UL 9540 certificate date
2024-04-29
UL 9540 certifying entity
Intertek
Firmware version(s) tested
V01.02.00
UL 1741 SB certificate date
[6/4/2024]
UL 1741 SB certifying entity
CSA Group
Certified JA12 control strategies
No Information Submitted
Maximum continuous discharge rate (kW)
11.4
Manufacturer-declared round-trip efficiency (%)
No Information Submitted

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECCPS-ESSR-ECH11.4US-60L1US {240V}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECCPS-ESSR-ECH11.4US-60L1US {208V}
    Archived CEC source