ELM Fieldsight LLC

CMG2-AC-107-215

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

ESS with Additional Devices

The figures below refer to CMG2-AC-107-215. Use the configuration table for other variants.

Controlled apparent power
107.5 kVA
Operating voltage
480 V
PCS functionality
ESS
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for CMG2-AC-107-215
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
CMG2-AC-107-215PCS Data for Inverter and ESS row 103107.5 kVA480 VListed in CEC

Source specifications and conditions

Additional source information for CMG2-AC-107-215. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Equipment type
ESS
CEC listing date
2026-05-01
Export-only mode
Y
Import-only mode
Y
No-exchange mode
Y
Unrestricted mode
N
Phase configuration
Multi
PCS CRD document date
2025-06-05
PCS CRD issuing entity
Bureau Veritas
Additional required devices
ELM Microgrid (FSCW-XXX) and either; Schweitzer Engineering Laboratories, SEL-751 Meter with AccuEnergy AcuCT-0812, AcuCT-2031, AcuCT-125R, AcuCT-200R, AcuCT-4161R, AcuCT-3135R, RCTYY CTs, or AccuEnergy Acuvim IIR-M-mV-P2v3 Meter with Continental Control Systems ACTL-1250, CTBL, CTRC, RSCSL, RSCLL and AccuEnergy RCTYY CTs.
Output voltage as reported (V)
480
Export-only response time (seconds)
2
Import-only response time (seconds)
2
No-exchange response time (seconds)
2
Current measurement reference points
ESS, External Meters, External CTs
Unrestricted response time (seconds)
N/A
Maximum apparent power as reported (kVA)
107.5
Maximum continuous current as reported (A)
171

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECCMG2-AC-107-215
    Archived CEC source