Enphase Energy, Inc.

ENCHARGE-3T-1P-NA

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

For Import Only Mode: Energy Storage System paired with Enphase IQ Combiner or Envoy for PCS functionality. May be paired with PV system, resulting in an increased maximum open loop response time of 9 seconds. For Export Only Mode: Energy Storage System paired with Enphase IQ Gateway for PCS functionality. May be paired with PV system, and/or Enphase IQ System Controller.

The figures below refer to ENCHARGE-3T-1P-NA. Use the configuration table for other variants.

Controlled apparent power
30.72 kVA
Operating voltage
240 V
PCS functionality
ESS
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for ENCHARGE-3T-1P-NA
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
ENCHARGE-3T-1P-NAPCS Data for Inverter and ESS row 24030.72 kVA240 VListed in CEC

Source specifications and conditions

Additional source information for ENCHARGE-3T-1P-NA. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
Maximum continuous current (128) and power (30.72) based on PV + ESS configuration. For ESS-only configuration, halve each (64 and 15.36). * For Import Only Mode, the open loop response time without PV input. With PV, the maximum open loop response time is 9 seconds.
Equipment type
ESS
CEC listing date
2021-07-21
Export-only mode
Y
Import-only mode
Y
No-exchange mode
N
Unrestricted mode
N
Source last update
2024-01-02
Phase configuration
Single
PCS CRD document date
8/25/2021 11/14/2023
PCS CRD issuing entity
UL [Import Only Mode] Bureau Veritas Consumer Product Services [Export Only Mode]
Additional required devices
For Import Only Mode: Enphase IQ Combiner or Envoy, Enphase CT-200-SPLIT, Enphase Enpower For Export Only Mode: Enphase IQ Gateway, at least one CT-200-SPLIT or CT-200-CLAMP for ESS, at least two CT-200-SPLIT or CT-200-CLAMP for consumption, at least one CT-200-SOLID for PV, Enphase IQ System Controller 3/3G (optional), Enphase IQ System Controller 2 (optional)
Output voltage as reported (V)
240
Export-only response time (seconds)
2
Import-only response time (seconds)
1.6*
No-exchange response time (seconds)
N/A
Current measurement reference points
For Import Only Mode: ESS & Enphase IQ Combiner or Envoy & Additional CT-200-SPLIT For Export Only Mode: ESS & Enphase IQ Gateway & external CTs. Enphase IQ System Controller 3/3G (optional). Enphase IQ System Controller 2 (optional)
Unrestricted response time (seconds)
N/A
Maximum apparent power as reported (kVA)
30.72
Maximum continuous current as reported (A)
128

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECENCHARGE-3T-1P-NA
    Archived CEC source