Enphase Energy, Inc.

IQ9N-3P-277-A-US

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

Enphase PV System paired with Enphase IQ Gateway for PCS functionality.

The figures below refer to IQ9N-3P-277-A-US {277V}. Use the configuration table for other variants.

Controlled apparent power
166.53 kVA
Operating voltage
277 V
PCS functionality
PV Inverter
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for IQ9N-3P-277-A-US
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
IQ9N-3P-277-A-US {277V}PCS Data for Inverter and ESS row 269166.53 kVA277 VListed in CEC

Source specifications and conditions

Additional source information for IQ9N-3P-277-A-US {277V}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
Import Only (Zero Export - PV Only) - This PCS mode evaluated the PV system for its ability not to export power to the grid. This mode is configured by making the Aggregate Power Export Limit set to zero. The Maximum Open Loop Response Time for this mode is 6.9 seconds when using Enphase IQ Gateway with Consumption CTs and 2 seconds when using IQ Gateway with Remote Meter.
Equipment type
PV Inverter
CEC listing date
2026-03-02
Export-only mode
N
Import-only mode
N
No-exchange mode
N
Unrestricted mode
N
Phase configuration
Multi
PCS CRD document date
2025-12-31
PCS CRD issuing entity
Bureau Veritas
Additional required devices
Enphase IQ Gateway Pro (GW0-1CL-1N-D0-0R) and for PV monitoring (at least 3 units CT-400-277-SOLID) and for consumption monitoring (at least 3 units of CT-600-277-SPLIT or a single Remote Meter, DTS310-3X-EB-X-X, paired with any 333mV Class 0.5 CT or Rogowski Coil, Xs are other wildcards)
Output voltage as reported (V)
277
Export-only response time (seconds)
N/A
Import-only response time (seconds)
N/A
No-exchange response time (seconds)
N/A
Current measurement reference points
Enphase IQ Gateway, External CTs or Remote Meter
Unrestricted response time (seconds)
N/A
Maximum apparent power as reported (kVA)
166.53
Maximum continuous current as reported (A)
601

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECIQ9N-3P-277-A-US {277V}
    Archived CEC source