Eternalplanet Energy Co., Ltd

EP Cube2 UL-S-25G

Legacy PCS · 4 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

ESS with Additional Devices

The figures below refer to EP Cube2 UL-S-25G {240V, 11.5kW}. Use the configuration table for other variants.

Controlled apparent power
34.5* kVA
Operating voltage
240 V
PCS functionality
ESS
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for EP Cube2 UL-S-25G
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
EP Cube2 UL-S-25G {240V, 11.5kW}PCS Data for Inverter and ESS row 29234.5* kVA240 VListed in CEC
EP Cube2 UL-S-25G {240V, 5.8kW}PCS Data for Inverter and ESS row 29334.5* kVA240 VListed in CEC
EP Cube2 UL-S-25G {240V, 7.6kW}PCS Data for Inverter and ESS row 29434.5* kVA240 VListed in CEC
EP Cube2 UL-S-25G {240V, 9.6kW}PCS Data for Inverter and ESS row 29534.5* kVA240 VListed in CEC

Source specifications and conditions

Additional source information for EP Cube2 UL-S-25G {240V, 11.5kW}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
*The reflected values are the highest Maximum Continuous Current and Maximum Continuous Power that the inlcuded gateway can control when multiple inputs are utilized.
Equipment type
ESS
CEC listing date
2026-08-03
Export-only mode
Y
Import-only mode
Y
No-exchange mode
N
Unrestricted mode
N
Phase configuration
Single
PCS CRD document date
2026-06-03
PCS CRD issuing entity
TUV Rheinland of North America
Additional required devices
Smart Gateway (SGNA2-200G1 or SGNA2-200G2, with built-in CT) for both Whole-Home and Partial-Home Backup (add External CT, ECSL24200-2-C2, for Partial-Home Backup).
Output voltage as reported (V)
240
Export-only response time (seconds)
1.948
Import-only response time (seconds)
1.868
No-exchange response time (seconds)
N/A
Current measurement reference points
Inverter, Gateway, External CT
Unrestricted response time (seconds)
N/A
Maximum apparent power as reported (kVA)
34.5*
Maximum continuous current as reported (A)
144*

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECEP Cube2 UL-S-25G {240V, 9.6kW}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECEP Cube2 UL-S-25G {240V, 7.6kW}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECEP Cube2 UL-S-25G {240V, 5.8kW}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECEP Cube2 UL-S-25G {240V, 11.5kW}
    Archived CEC source