Equipment overview

400 W, 264 cell CdTe thin film with anti-reflective coating, 1500V max system Vdc

The figures below refer to FS-6400A. Use the configuration table for other variants.

Nameplate DC power
400 W DC
Maximum-power voltage (DC)
176.1 V DC
PTC power (DC)
375.2 W DC
Technology
CdTe

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for FS-6400A
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
FS-6400APV Module-Full row 3602400 W DC375.2 W DCListed in CEC

Source specifications and conditions

Additional source information for FS-6400A. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
49.64
Module family
Thin Film
Cells in series
264
CEC listing date
2018-12-17
Module area (m²)
2.48
PTC rating (W DC)
375.2
Safety certification
UL 1703
Building-integrated PV
N
Maximum-power current Imp (A)
2.27
Short-circuit current Isc (A)
2.51
Open-circuit voltage Voc (V DC)
216.1
Maximum-power voltage Vmp (V DC)
176.1
Pmax temperature coefficient (%/°C)
-0.24445

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECFS-6400A
    Archived CEC source