Equipment overview

525 W, 268 cell CdTe thin film module with anti-reflective coating, 1500V max system Vdc

The figures below refer to FS-7525A-TR1. Use the configuration table for other variants.

Nameplate DC power
525 W DC
Maximum-power voltage (DC)
186 V DC
PTC power (DC)
488.4 W DC
Technology
CdTe

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for FS-7525A-TR1
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
FS-7525A-TR1PV Module-Full row 3733525 W DC488.4 W DCListed in CEC

Source specifications and conditions

Additional source information for FS-7525A-TR1. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
48.94
Module family
Thin Film
Cells in series
268
CEC listing date
2023-09-11
Module area (m²)
2.8
PTC rating (W DC)
488.4
Source last update
2024-07-22
Safety certification
UL 61730
Parallel cell strings
1
Building-integrated PV
N
Maximum-power current Imp (A)
2.82
Short-circuit current Isc (A)
3.04
Open-circuit voltage Voc (V DC)
226.1
Maximum-power voltage Vmp (V DC)
186
Pmax temperature coefficient (%/°C)
-0.2947

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECFS-7525A-TR1
    Archived CEC source