A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.
How to use this dataEquipment overview
ESS with PCS functionality
The figures below refer to GECS11.4-US20 {11.4kW, 12.8kWh}. Use the configuration table for other variants.
- Controlled apparent power
- 11.4 kVA
- Operating voltage
- 240 V
- PCS functionality
- ESS
- Technology
- Not reported
Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.
Exact configurations
CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.
| CEC model / configuration | Controlled apparent power | Voltage / display | Observation | Compare |
|---|---|---|---|---|
| GECS11.4-US20 {11.4kW, 12.8kWh}PCS Data for Inverter and ESS row 593 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 16kWh}PCS Data for Inverter and ESS row 594 · PCS Data for Inverter and ESS row 595 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 19.2kWh}PCS Data for Inverter and ESS row 596 · PCS Data for Inverter and ESS row 597 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 25.6kWh}PCS Data for Inverter and ESS row 598 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 28.8kWh}PCS Data for Inverter and ESS row 599 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 32kWh}PCS Data for Inverter and ESS row 600 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 38.4kWh}PCS Data for Inverter and ESS row 601 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 48kWh}PCS Data for Inverter and ESS row 602 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 51.2kWh}PCS Data for Inverter and ESS row 603 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 57.6kWh}PCS Data for Inverter and ESS row 604 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 64kWh}PCS Data for Inverter and ESS row 605 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 76.8kWh}PCS Data for Inverter and ESS row 606 | 11.4 kVA | 240 V | Listed in CEC | |
| GECS11.4-US20 {11.4kW, 9.6kWh}PCS Data for Inverter and ESS row 607 · PCS Data for Inverter and ESS row 608 | 11.4 kVA | 240 V | Listed in CEC |
Source specifications and conditions
Additional source information for GECS11.4-US20 {11.4kW, 12.8kWh}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.
- Equipment type
- ESS
- CEC listing date
- 2023-02-13
- Export-only mode
- N
- Import-only mode
- Y
- No-exchange mode
- Y
- Unrestricted mode
- N
- Phase configuration
- Single
- PCS CRD document date
- 2022-07-19
- PCS CRD issuing entity
- CSA Group
- Additional required devices
- Either a meter (GMK120, GMK121, GMK140, or GMK141), or an automatic backup device (ABD200-40-US10, ABD200-63-US10 ABD100-40-US10, or ABD100-63-US10).
- Output voltage as reported (V)
- 240
- Export-only response time (seconds)
- N/A
- Import-only response time (seconds)
- 15.256
- No-exchange response time (seconds)
- 3.731
- Current measurement reference points
- ESS & External CT (from the meter or the automatic backup device)
- Unrestricted response time (seconds)
- N/A
- Maximum apparent power as reported (kVA)
- 11.4
- Maximum continuous current as reported (A)
- 47.5
Use the source row references above to inspect the conditions for each other configuration.
Documented compatibility
No specific equipment pairing has been verified for this model.
Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.
Registry observation history
Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.
- Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 9.6kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 76.8kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 64kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 57.6kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 51.2kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 48kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 38.4kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 32kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 28.8kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 25.6kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 19.2kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 16kWh}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGECS11.4-US20 {11.4kW, 12.8kWh}
Archived CEC source