Equipment overview

7.6 kW, 10.6 kWh, 240 Vac lithium ion energy storage system

The figures below refer to GEHS7.6-US20 {7.6kW, 10.6kWh}. Use the configuration table for other variants.

Nameplate power
7.6 kW
Nominal AC voltage
240 V AC
Nameplate energy capacity
10.6 kWh
Technology
Lithium Ion
UL 1741 SB in CEC source
Reported
JA12 declaration
N

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for GEHS7.6-US20
CEC model / configurationNameplate powerCapacityObservationCompare
GEHS7.6-US20 {7.6kW, 10.6kWh}Energy Storage System row 26567.6 kW10.6 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 12.8kWh}Energy Storage System row 27007.6 kW12.8 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 14.1kWh}Energy Storage System row 27227.6 kW14.1 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 16kWh}Energy Storage System row 27887.6 kW16 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 17.7kWh}Energy Storage System row 28127.6 kW17.7 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 19.2kWh}Energy Storage System row 28787.6 kW19.2 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 25.6kWh}Energy Storage System row 29327.6 kW25.6 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 28.8kWh}Energy Storage System row 29527.6 kW28.8 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 32kWh}Energy Storage System row 29947.6 kW32 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 38.4kWh}Energy Storage System row 30227.6 kW38.4 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 48kWh}Energy Storage System row 30427.6 kW48 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 51.2kWh}Energy Storage System row 30627.6 kW51.2 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 57.6kWh}Energy Storage System row 30827.6 kW57.6 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 64kWh}Energy Storage System row 31027.6 kW64 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 76.8kWh}Energy Storage System row 31227.6 kW76.8 kWhListed in CEC
GEHS7.6-US20 {7.6kW, 9.6kWh}Energy Storage System row 26027.6 kW9.6 kWhListed in CEC

Source specifications and conditions

Additional source information for GEHS7.6-US20 {7.6kW, 10.6kWh}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

CEC listing date
2024-07-11
PV DC input capability
Y
UL 9540 certificate date
2024-03-15
UL 9540 certifying entity
SGS
Firmware version(s) tested
No Information Submitted
UL 1741 SB certificate date
[7/19/2022]
UL 1741 SB certifying entity
CSA Group
Certified JA12 control strategies
No Information Submitted
Maximum continuous discharge rate (kW)
5
Manufacturer-declared round-trip efficiency (%)
No Information Submitted

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 76.8kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 64kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 57.6kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 51.2kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 48kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 38.4kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 32kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 28.8kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 25.6kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 19.2kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 17.7kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 16kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 14.1kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 12.8kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 10.6kWh}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECGEHS7.6-US20 {7.6kW, 9.6kWh}
    Archived CEC source