Hansol Technics Co., Ltd.

HS305UB-JH2

Solar panel · 2 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

305 W, 120 half-cut cell monocrystalline module, black backsheet, 1500V max system Vdc

The figures below refer to HS305UB-JH2 {Blk}. Use the configuration table for other variants.

Nameplate DC power
305 W DC
Maximum-power voltage (DC)
33.9 V DC
PTC power (DC)
283.5 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for HS305UB-JH2
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
HS305UB-JH2 {Blk}PV Module-Full row 4880305 W DC283.5 W DCListed in CEC
HS305UB-JH2 {Wht}PV Module-Full row 4881305 W DC285.3 W DCListed in CEC

Source specifications and conditions

Additional source information for HS305UB-JH2 {Blk}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
44.96
Module family
Monocrystalline
Cells in series
60
CEC listing date
2019-07-01
Module area (m²)
1.611
PTC rating (W DC)
283.5
Safety certification
UL 1703
Parallel cell strings
2
Building-integrated PV
N
Maximum-power current Imp (A)
9
Short-circuit current Isc (A)
9.63
Open-circuit voltage Voc (V DC)
40
Maximum-power voltage Vmp (V DC)
33.9
Pmax temperature coefficient (%/°C)
-0.359

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECHS305UB-JH2 {Wht}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECHS305UB-JH2 {Blk}
    Archived CEC source