HSL60P6-PA-4-240TB
Solar panel · 1 exact configuration · California, US
A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.
How to use this dataEquipment overview
240 W Polycrystalline Module, 1000 V System Voltage, Black Backsheet, Black Frame
The figures below refer to HSL60P6-PA-4-240TB. Use the configuration table for other variants.
- Nameplate DC power
- 240 W DC
- Maximum-power voltage (DC)
- 29.5 V DC
- PTC power (DC)
- 215.9 W DC
- Technology
- Multi-c-Si
Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.
Exact configurations
CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.
| CEC model / configuration | Nameplate DC power | PTC (DC) | Observation | Compare |
|---|---|---|---|---|
| HSL60P6-PA-4-240TBPV Module-Full row 5193 | 240 W DC | 215.9 W DC | Listed in CEC |
Source specifications and conditions
Additional source information for HSL60P6-PA-4-240TB. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.
- Mounting
- Rack
- NOCT (°C)
- 46.1
- Module type
- Flat Plate
- Source notes
- Formerly listed under Hanwha Q CELLS (Qidong)
- Long side (m)
- 1.652
- Module family
- Polycrystalline
- Short side (m)
- 1
- Cells in series
- 60
- Module area (m²)
- 1.652
- PTC rating (W DC)
- 215.9
- Safety certification
- UL 1703
- Parallel cell strings
- 1
- Building-integrated PV
- N
- Maximum-power current Imp (A)
- 8.13
- Short-circuit current Isc (A)
- 8.75
- Open-circuit voltage Voc (V DC)
- 37.1
- Maximum-power voltage Vmp (V DC)
- 29.5
- Pmax temperature coefficient (%/°C)
- -0.45
Documented compatibility
No specific equipment pairing has been verified for this model.
Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.
Registry observation history
Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.
- Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECHSL60P6-PA-4-240TB
Archived CEC source