Heliene

96P435

Solar panel · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

435 W Polycrystalline Module

The figures below refer to 96P435. Use the configuration table for other variants.

Nameplate DC power
435 W DC
Maximum-power voltage (DC)
50.525 V DC
PTC power (DC)
390.1 W DC
Technology
Multi-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for 96P435
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
96P435PV Module-Full row 5872435 W DC390.1 W DCListed in CEC

Source specifications and conditions

Additional source information for 96P435. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Mounting
Rack
NOCT (°C)
47.7
Module type
Flat Plate
Long side (m)
1.943
Module family
Polycrystalline
Short side (m)
1.2970000000000002
Cells in series
96
Module area (m²)
2.520071
PTC rating (W DC)
390.1
Safety certification
UL 1703
Parallel cell strings
1
Building-integrated PV
N
Maximum-power current Imp (A)
8.658999999999999
Short-circuit current Isc (A)
9.135000000000002
Open-circuit voltage Voc (V DC)
61.725
Maximum-power voltage Vmp (V DC)
50.525
Pmax temperature coefficient (%/°C)
-0.449

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.