7.6 kW, 208 Vac Grid Support Utility Interactive PV and Battery Inverter

The figures below refer to LNT7K0228UL {208V}. Use the configuration table for other variants.

Continuous AC output
7.648 kW
Nominal AC voltage
208 V AC
CEC weighted efficiency
96.5 %
Technology
Hybrid inverter
UL 1741 SB in CEC source
Reported
CEC source lists
Solar + Battery

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for LNT7K0228UL
CEC model / configurationContinuous AC outputVoltage / displayObservationCompare
LNT7K0228UL {208V}Solar_Inverters row 1238 · Battery_Inverters row 5257.648 kW208 V ACListed in CEC
LNT7K0228UL {240V}Solar_Inverters row 1237 · Battery_Inverters row 5247.647 kW240 V ACListed in CEC

Source specifications and conditions

Additional source information for LNT7K0228UL {208V}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Built-in meter
N
Firmware version(s) tested
No Information Submitted
UL 1741 SA certificate date
No Information Submitted
UL 1741 SB certificate date
[5/30/2024]
CSIP conformance as reported
N
UL 1741 SA certifying entity
No Information Submitted
UL 1741 SB certifying entity
SGS
CEC grid-support listing date
2024-09-11

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECLNT7K0228UL {208V}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECLNT7K0228UL {240V}
    Archived CEC source