ESS with Additional Devices
The figures below refer to Q.HOME CORE A7.6B13.1. Use the configuration table for other variants.
- Controlled apparent power
- 23* kVA
- Operating voltage
- 240 V
- PCS functionality
- ESS
- Technology
- Not reported
Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.
Exact configurations
CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.
| CEC model / configuration | Controlled apparent power | Voltage / display | Observation | Compare |
|---|---|---|---|---|
| Q.HOME CORE A7.6B13.1PCS Data for Inverter and ESS row 1312 | 23* kVA | 240 V | Listed in CEC |
Source specifications and conditions
Additional source information for Q.HOME CORE A7.6B13.1. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.
- Source notes
- *For Import Only Mode the Maximum Open Loop Response Time is 0.652 seconds for backup configuration using the Q.HOME HUB 200G device. The Maximum Continuous Power and Current for this configuration is 31.7A and 7.6kVA (without PV). The listed power and current ratings are for Max ESS and PV configurations.
- Equipment type
- ESS
- CEC listing date
- 2024-08-01
- Export-only mode
- Y
- Import-only mode
- Y
- No-exchange mode
- Y
- Unrestricted mode
- Y
- Source last update
- 2026-07-01
- Phase configuration
- Single
- PCS CRD document date
- 2025-07-29
- PCS CRD issuing entity
- Intertek
- Additional required devices
- External CTs: XH-SCT-S24-200A/80mA or XH-SCT-S21-200A/80mA or CT-HQ-SOLID-200A PV Inverter: Q.MI.349B-G1 AC Combiner: Q.HOME COMBINER 80 G1 Backup Configuration: Q.HOME HUB 200G
- Output voltage as reported (V)
- 240
- Export-only response time (seconds)
- 1.47
- Import-only response time (seconds)
- 1.43*
- No-exchange response time (seconds)
- 1.25
- Current measurement reference points
- External CTs, PV Inverter, AC Combiner, Hub (for backup configuration using Import Only Mode)
- Unrestricted response time (seconds)
- 1.27
- Maximum apparent power as reported (kVA)
- 23*
- Maximum continuous current as reported (A)
- 95.5*
Documented compatibility
No specific equipment pairing has been verified for this model.
Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.
Registry observation history
Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.
- Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECQ.HOME CORE A7.6B13.1
Archived CEC source