Qcells North America

Q.PEAK DUO BLK ML-G10.C1+/AC 415

Solar panel · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

415 W, 132 half-cut cell monocrystalline, black backsheet, ACPV Module. DC Module: Q.PEAK DUO BLK ML-G10+ 415. Microinverter: Q.MI.349B-G1.

The figures below refer to Q.PEAK DUO BLK ML-G10.C1+/AC 415. Use the configuration table for other variants.

Nameplate DC power
415 W DC
Maximum-power voltage (DC)
37.89 V DC
PTC power (DC)
390.7 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for Q.PEAK DUO BLK ML-G10.C1+/AC 415
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
Q.PEAK DUO BLK ML-G10.C1+/AC 415PV Module-Full row 12701415 W DC390.7 W DCListed in CEC

Source specifications and conditions

Additional source information for Q.PEAK DUO BLK ML-G10.C1+/AC 415. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
43.6
Source notes
This component is specific to ACPV and is not available individually.
Module family
Monocrystalline
Cells in series
66
CEC listing date
2026-01-21
Module area (m²)
1.91
PTC rating (W DC)
390.7
Safety certification
UL 1741
Parallel cell strings
2
Building-integrated PV
N
Maximum-power current Imp (A)
10.95
Short-circuit current Isc (A)
11.23
Open-circuit voltage Voc (V DC)
45.41
Maximum-power voltage Vmp (V DC)
37.89
Pmax temperature coefficient (%/°C)
-0.337

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECQ.PEAK DUO BLK ML-G10.C1+/AC 415
    Archived CEC source