Qcells North America

Q.TRON BLK M-G2+/AC 405

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

349 W, 405 Wdc, AC PV module with integrated microinverter Q.MI.349G-B1. PCS functionality, PEL, backfeed power limit.

The figures below refer to Q.TRON BLK M-G2+/AC 405. Use the configuration table for other variants.

Controlled apparent power
0.349 kVA
Operating voltage
240 V
PCS functionality
ACPV
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for Q.TRON BLK M-G2+/AC 405
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
Q.TRON BLK M-G2+/AC 405PCS Data for Inverter and ESS row 13140.349 kVA240 VListed in CEC

Source specifications and conditions

Additional source information for Q.TRON BLK M-G2+/AC 405. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Equipment type
ACPV
CEC listing date
2025-04-11
Export-only mode
N
Import-only mode
N
No-exchange mode
N
Unrestricted mode
N
Phase configuration
Single
PCS CRD document date
2024-12-17
PCS CRD issuing entity
Intertek
Additional required devices
Q.HOME COMBINER 80 G1, Consumption CT: XH-SCT-S24-200A, Production CT: CT-HQ-SOLID-200A
Output voltage as reported (V)
240
Export-only response time (seconds)
N/A
Import-only response time (seconds)
N/A
No-exchange response time (seconds)
N/A
Current measurement reference points
Q.HOME Combiner and CTs
Unrestricted response time (seconds)
N/A
Maximum apparent power as reported (kVA)
0.349
Maximum continuous current as reported (A)
1.45

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECQ.TRON BLK M-G2+/AC 405