Qcells North America

Q.VOLT A7.6SX

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

Inverter with PCS functionality used in combination with external Backup Interface (Q.HOME HUB 200SX)

The figures below refer to Q.VOLT A7.6SX. Use the configuration table for other variants.

Controlled apparent power
7.608 kVA
Operating voltage
240 V
PCS functionality
Inverter
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for Q.VOLT A7.6SX
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
Q.VOLT A7.6SXPCS Data for Inverter and ESS row 13197.608 kVA240 VListed in CEC

Source specifications and conditions

Additional source information for Q.VOLT A7.6SX. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Equipment type
Inverter
CEC listing date
2023-05-11
Export-only mode
Y
Import-only mode
Y
No-exchange mode
Y
Unrestricted mode
Y
Source last update
2024-06-03
Phase configuration
Single
PCS CRD document date
2024-02-23
PCS CRD issuing entity
CSA Group
Additional required devices
Whole home backup: Backup Interface Q.HOME HUB 200SX (with two integrated CTs) Partial home backup: Backup Interface Q.HOME HUB 200SX, and two external CTs (CTSA024-XXXX/YYYY)
Output voltage as reported (V)
240
Export-only response time (seconds)
1.88
Import-only response time (seconds)
1.98
No-exchange response time (seconds)
1.88
Current measurement reference points
Inverter, Backup Interface (BI) and CTs
Unrestricted response time (seconds)
1.96
Maximum apparent power as reported (kVA)
7.608
Maximum continuous current as reported (A)
31.7

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECQ.VOLT A7.6SX
    Archived CEC source