REC Group

REC350TP2S 72 XV

Solar panel · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

350 W, 144 half cell polycrystalline module, white backsheet, 1500V max system Vdc

The figures below refer to REC350TP2S 72 XV. Use the configuration table for other variants.

Nameplate DC power
350 W DC
Maximum-power voltage (DC)
38.9 V DC
PTC power (DC)
319 W DC
Technology
Multi-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for REC350TP2S 72 XV
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
REC350TP2S 72 XVPV Module-Full row 13096350 W DC319 W DCListed in CEC

Source specifications and conditions

Additional source information for REC350TP2S 72 XV. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Mounting
Rack
NOCT (°C)
44.26
Module type
Flat Plate
Long side (m)
2.005
Module family
Polycrystalline
Short side (m)
1.001
Cells in series
72
Module area (m²)
1.95
PTC rating (W DC)
319
Source last update
2024-04-11
Safety certification
UL 61730
Parallel cell strings
2
Building-integrated PV
N
Maximum-power current Imp (A)
9
Short-circuit current Isc (A)
9.72
Open-circuit voltage Voc (V DC)
46.7
Maximum-power voltage Vmp (V DC)
38.9
Pmax temperature coefficient (%/°C)
-0.46

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECREC350TP2S 72 XV