Shenzhen Senergy Technology Co., Ltd.

SE 10KHB-210-T2/UL

Legacy PCS · 2 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

ESS with Additional Devices

The figures below refer to SE 10KHB-210-T2/UL {208V}. Use the configuration table for other variants.

Controlled apparent power
11 kVA
Operating voltage
208 V
PCS functionality
ESS
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for SE 10KHB-210-T2/UL
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
SE 10KHB-210-T2/UL {208V}PCS Data for Inverter and ESS row 143711 kVA208 VListed in CEC
SE 10KHB-210-T2/UL {240V}PCS Data for Inverter and ESS row 143811 kVA240 VListed in CEC

Source specifications and conditions

Additional source information for SE 10KHB-210-T2/UL {208V}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
Power Control System test report confirms compliance with UL 1741 CRD (dated: April 8, 2023) and UL 3141 (dated: October 9, 2024)
Equipment type
ESS
CEC listing date
2025-06-23
Export-only mode
Y
Import-only mode
Y
No-exchange mode
Y
Unrestricted mode
Y
Phase configuration
Single
PCS CRD document date
2025-03-13
PCS CRD issuing entity
TUV Rheinland
Additional required devices
CTSA024 or HY94C82
Output voltage as reported (V)
208
Export-only response time (seconds)
5
Import-only response time (seconds)
5
No-exchange response time (seconds)
5
Current measurement reference points
Inverter, External Sensors
Unrestricted response time (seconds)
5
Maximum apparent power as reported (kVA)
11
Maximum continuous current as reported (A)
45.8

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECSE 10KHB-210-T2/UL {240V}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECSE 10KHB-210-T2/UL {208V}
    Archived CEC source