Silfab Solar Inc.

SIL300BL

Solar panel · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

300 W, 126 cell monocrystalline module, black backsheet

The figures below refer to SIL300BL. Use the configuration table for other variants.

Nameplate DC power
300 W DC
Maximum-power voltage (DC)
32.99 V DC
PTC power (DC)
267.9 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for SIL300BL
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
SIL300BLPV Module-Full row 15158300 W DC267.9 W DCListed in CEC

Source specifications and conditions

Additional source information for SIL300BL. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
48.2
Module family
Monocrystalline
Cells in series
21
CEC listing date
2019-09-03
Module area (m²)
1.6650690000000001
PTC rating (W DC)
267.9
Safety certification
UL 1703
Parallel cell strings
6
Building-integrated PV
N
Maximum-power current Imp (A)
9.07933333333333
Short-circuit current Isc (A)
9.80895238095238
Open-circuit voltage Voc (V DC)
38.6880952380952
Maximum-power voltage Vmp (V DC)
32.99
Pmax temperature coefficient (%/°C)
-0.462

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECSIL300BL
    Archived CEC source