Equipment overview

715 W, 132 half-cut cell bifacial monocrystalline module, sliver frame, 1500V max system Vdc

The figures below refer to SKY 715-BHDG24-USA. Use the configuration table for other variants.

Nameplate DC power
715 W DC
Maximum-power voltage (DC)
42.54 V DC
PTC power (DC)
681.5 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for SKY 715-BHDG24-USA
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
SKY 715-BHDG24-USAPV Module-Full row 15427715 W DC681.5 W DCListed in CEC

Source specifications and conditions

Additional source information for SKY 715-BHDG24-USA. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
45.59
Module family
Monocrystalline
Cells in series
66
CEC listing date
2024-07-22
Module area (m²)
3.11
PTC rating (W DC)
681.5
Safety certification
UL 61730
Parallel cell strings
2
Building-integrated PV
N
Maximum-power current Imp (A)
16.81
Short-circuit current Isc (A)
17.61
Open-circuit voltage Voc (V DC)
50.59
Maximum-power voltage Vmp (V DC)
42.54
Pmax temperature coefficient (%/°C)
-0.2489

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.