SolarEdge Technologies Ltd.

NXx00T-US

Power control system · 6 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

ESS discharge 0% to grid; only PV discharge to grid

The figures below refer to NXx00T-US. Use the configuration table for other variants.

Controlled active power
13 kW
Operating voltage
208/240 V
PCS functionality
ESS Import Only Mode
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for NXx00T-US
CEC model / configurationControlled active powerVoltage / displayObservationCompare
NXx00T-USPower Control Systems row 10813 kW208/240 VListed in CEC
NXx00T-USPower Control Systems row 10713 kW240 VListed in CEC
NXx00T-USPower Control Systems row 10613 kW208/240 VListed in CEC
NXx00T-USPower Control Systems row 11013 kW208/240 VListed in CEC
NXx00T-USPower Control Systems row 10513 kW240 VListed in CEC
NXx00T-USPower Control Systems row 10913 kW240 VListed in CEC

Source specifications and conditions

Additional source information for NXx00T-US. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
where x = 38, 50, 57, 60, 76, 96, 100, 115, 130
UL 3141 edition
OOI Issue 2 : 2024
CEC listing date
2026-08-05
PCS functionality
ESS Import Only Mode
Phase configuration
L-N/L-L
Integrated end product
Inverter
Scheduling conformance
No
UL 3141 certificate date
2026-07-17
UL 3141 certifying entity
Intertek/ETL
Additional required devices
Inverter (NXx00T-US), Battery (NX-BLCK-5K, NX-BLCK-5K-SR, or NX-BLCK-5K-NB), DC Link (NX-LNK), Meter Collar (V1-D-SE)
Maximum controlled current (A)
54
Rated operating voltage(s) (V)
208/240
Time to steady state (seconds)
6.45
Maximum response time (seconds)
0.05
Current measurement reference points
Point Of Common Coupling (PCC)
Maximum controlled active power (kW)
13

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECNXx00T-US
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECNXx00T-US
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECNXx00T-US
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECNXx00T-US
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECNXx00T-US
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECNXx00T-US
    Archived CEC source