SolaX Power Network Technology (Zhe jiang) Co., Ltd.

A1-HYB-5.0K-G2

Legacy PCS · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

Inverter with PCS functionality used in combination with external Backup Interface (A1-BI-200-G2 or A1-BI PRO-200-G2)

The figures below refer to A1-HYB-5.0K-G2 {240V}. Use the configuration table for other variants.

Controlled apparent power
5.016 kVA
Operating voltage
240 V
PCS functionality
Inverter
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for A1-HYB-5.0K-G2
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
A1-HYB-5.0K-G2 {240V}PCS Data for Inverter and ESS row 16685.016 kVA240 VListed in CEC

Source specifications and conditions

Additional source information for A1-HYB-5.0K-G2 {240V}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
*The listed Maximum Open Loop Response Times (MOLRTs) is related to the PCS configuration with or without the External Sensor (CT), CTSA024 XXXX/YYYY, the MOLRTs for the configuration using the External Sensor Power Meter Module are listed below: Unrestricted Mode 1.86 seconds Export Only Mode 1.3 seconds Import Only Mode 1.56 seconds No Exchange Mode 1.78 second **The listed Maximum Open Loop Response Time (MOLRT) is related to the PCS configuration using the External Sensor Power Meter Module, the MOLRT for the configuration with or without the External Sensor (CT), CTSA024 XXXX/YYYY is listed below: No Exchange Mode 1.7 seconds
Equipment type
Inverter
CEC listing date
2023-04-11
Export-only mode
Y
Import-only mode
Y
No-exchange mode
Y
Unrestricted mode
Y
Source last update
2025-11-03
Phase configuration
Single
PCS CRD document date
2024-12-09
PCS CRD issuing entity
CSA Group
Additional required devices
Power Meter Module (AGF-AE-D/200) or Backup Interface (A1-BI-200-G2 or A1-BI PRO-200-G2) with or without External Sensor CT (CTSA024-XXXX/YYYY)
Output voltage as reported (V)
240
Export-only response time (seconds)
2*
Import-only response time (seconds)
1.98*
No-exchange response time (seconds)
1.78**
Current measurement reference points
Inverter, Backup Interface (BI), or External Sensor Power Meter Module or External CTs (if present)
Unrestricted response time (seconds)
1.92*
Maximum apparent power as reported (kVA)
5.016
Maximum continuous current as reported (A)
20.9

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECA1-HYB-5.0K-G2 {240V}
    Archived CEC source