T-Solar Global

TS370

Solar panel · 1 exact configuration · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

370 W Thin Film Single Junction Amorphous Silicon Module

The figures below refer to TS370. Use the configuration table for other variants.

Nameplate DC power
370 W DC
Maximum-power voltage (DC)
141 V DC
PTC power (DC)
343.6 W DC
Technology
Thin Film

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for TS370
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
TS370PV Module-Full row 19285370 W DC343.6 W DCListed in CEC

Source specifications and conditions

Additional source information for TS370. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Mounting
Rack
NOCT (°C)
44.8
Module type
Flat Plate
Long side (m)
2.598
Module family
Thin Film
Short side (m)
2.198
Cells in series
216
Module area (m²)
5.710404
PTC rating (W DC)
343.6
Safety certification
UL 1703
Parallel cell strings
12
Building-integrated PV
N
Maximum-power current Imp (A)
2.71
Short-circuit current Isc (A)
3.24
Open-circuit voltage Voc (V DC)
185
Maximum-power voltage Vmp (V DC)
141
Pmax temperature coefficient (%/°C)
-0.3

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.