Tangshan Haitai New Energy Technology Co., Ltd.

HTM595MH8-60(1500)

Solar panel · 2 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

595 W, 120 cell monocrystalline module, black backsheet, 1500V max system Vdc

The figures below refer to HTM595MH8-60(1500). Use the configuration table for other variants.

Nameplate DC power
595 W DC
Maximum-power voltage (DC)
34.62 V DC
PTC power (DC)
559 W DC
Technology
Mono-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for HTM595MH8-60(1500)
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
HTM595MH8-60(1500)PV Module-Full row 17377595 W DC559 W DCListed in CEC
HTM595MH8-60(1500)PV Module-Full row 17378595 W DC555.3 W DCListed in CEC

Source specifications and conditions

Additional source information for HTM595MH8-60(1500). Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
45.6
Module family
Monocrystalline
Cells in series
60
CEC listing date
2023-07-03
Module area (m²)
2.24
PTC rating (W DC)
559
Safety certification
UL 61730
Parallel cell strings
2
Building-integrated PV
N
Maximum-power current Imp (A)
17.19
Short-circuit current Isc (A)
18.15
Open-circuit voltage Voc (V DC)
40.97
Maximum-power voltage Vmp (V DC)
34.62
Pmax temperature coefficient (%/°C)
-0.345

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECHTM595MH8-60(1500)
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECHTM595MH8-60(1500)
    Archived CEC source