A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.
How to use this dataEquipment overview
Energy Storage System paired with Tesla Site Controller for PCS functionality, may be paired with PV system
The figures below refer to 1748844-XX-Y {2hr}. Use the configuration table for other variants.
- Controlled apparent power
- 20000 kVA
- Operating voltage
- 480 V
- PCS functionality
- ESS
- Technology
- Not reported
Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.
Exact configurations
CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.
| CEC model / configuration | Controlled apparent power | Voltage / display | Observation | Compare |
|---|---|---|---|---|
| 1748844-XX-Y {2hr}PCS Data for Inverter and ESS row 1709 | 20000 kVA | 480 V | Listed in CEC | |
| 1748844-XX-Y {3hr}PCS Data for Inverter and ESS row 1710 | 20000 kVA | 480 V | Listed in CEC | |
| 1748844-XX-Y {4hr}PCS Data for Inverter and ESS row 1711 | 20000 kVA | 480 V | Listed in CEC |
Source specifications and conditions
Additional source information for 1748844-XX-Y {2hr}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.
- Source notes
- The "Megapack 2" System scales up to 3 MWh+. A single 2 hour Megapack 2 can consist from 1 to 18 inverters and battery pods subsystems. Maximum continuous current and power are based on the largest scalable configuration of Megapack 2.
- Equipment type
- ESS
- CEC listing date
- 2023-04-21
- Export-only mode
- N
- Import-only mode
- Y
- No-exchange mode
- N
- Unrestricted mode
- N
- Phase configuration
- Multi
- PCS CRD document date
- 2022-11-16
- PCS CRD issuing entity
- TUV Rheinland of North America
- Additional required devices
- Tesla Site Controller (1471208-XX-Y), Site Meter (SEL-735), and compatible CTs
- Output voltage as reported (V)
- 480
- Export-only response time (seconds)
- N/A
- Import-only response time (seconds)
- 0.95
- No-exchange response time (seconds)
- N/A
- Current measurement reference points
- Inverter, Site Meter, and compatible CTs
- Unrestricted response time (seconds)
- N/A
- Maximum apparent power as reported (kVA)
- 20000
- Maximum continuous current as reported (A)
- 24000
Use the source row references above to inspect the conditions for each other configuration.
Documented compatibility
No specific equipment pairing has been verified for this model.
Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.
Registry observation history
Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.
- Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CEC1748844-XX-Y {4hr}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CEC1748844-XX-Y {3hr}
Archived CEC source - Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CEC1748844-XX-Y {2hr}
Archived CEC source