Tesla Inc.

Powerpack 2 system

Legacy PCS · 2 exact configurations · California, US

Choose a configuration ↓
i

A registry listing is a starting point. CEC inclusion is not nationwide installation approval. Confirm the exact model and configuration with your utility and local authority.

How to use this data

Equipment overview

Energy Storage System paired with Tesla Site Controller for PCS functionality, may be paired with PV system

The figures below refer to Powerpack 2 system {2hr}. Use the configuration table for other variants.

Controlled apparent power
20000 kVA
Operating voltage
480 V
PCS functionality
ESS
Technology
Not reported

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for Powerpack 2 system
CEC model / configurationControlled apparent powerVoltage / displayObservationCompare
Powerpack 2 system {2hr}PCS Data for Inverter and ESS row 171920000 kVA480 VListed in CEC
Powerpack 2 system {4hr}PCS Data for Inverter and ESS row 172020000 kVA480 VListed in CEC

Source specifications and conditions

Additional source information for Powerpack 2 system {2hr}. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

Source notes
The Powerpack System scales from 100 kWh+ to 100 MWh+. A single Powerpack can consist from 1 to 10 inverters and from 1 to 20 battery pods. Maximum continuous current and power are based on the largest scalable configuration of Powerpack.
Equipment type
ESS
CEC listing date
2020-12-21
Export-only mode
N
Import-only mode
Y
No-exchange mode
N
Unrestricted mode
N
Phase configuration
Multi
PCS CRD document date
2020-11-20
PCS CRD issuing entity
Intertek
Additional required devices
Tesla Site Controller & Accuenergy Acuvim II Meter & compatible CTs
Output voltage as reported (V)
480
Export-only response time (seconds)
N/A
Import-only response time (seconds)
1.764
No-exchange response time (seconds)
N/A
Current measurement reference points
Accuenergy Acuvim II Meter & compatible CTs
Unrestricted response time (seconds)
N/A
Maximum apparent power as reported (kVA)
20000
Maximum continuous current as reported (A)
24000

Use the source row references above to inspect the conditions for each other configuration.

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.

  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECPowerpack 2 system {4hr}
    Archived CEC source
  • Sep 21, 2026 · California Energy CommissionFirst observed: Listed in CECPowerpack 2 system {2hr}
    Archived CEC source