Equipment overview

350 W, 72 cell polycrystalline module, white backsheet, 1500V or 1000V or 600V max system Vdc

The figures below refer to WS-350. Use the configuration table for other variants.

Nameplate DC power
350 W DC
Maximum-power voltage (DC)
38.9 V DC
PTC power (DC)
319 W DC
Technology
Multi-c-Si

Specifications are reported in the CEC source; SolarApprovals has not independently tested this equipment. A missing value does not mean zero or a failed certification.

Exact configurations

CEC annotations in braces identify the listed configuration and are not part of the manufacturer’s model number. Variants share this canonical page.

Exact CEC configurations for WS-350
CEC model / configurationNameplate DC powerPTC (DC)ObservationCompare
WS-350PV Module-Full row 21157350 W DC319 W DCListed in CEC

Source specifications and conditions

Additional source information for WS-350. Qualifiers, reported control modes and required devices are retained as written. Power-control listings do not establish arbitrary battery/inverter pairings.

NOCT (°C)
45.3
Module family
Polycrystalline
Cells in series
72
CEC listing date
2019-11-15
Module area (m²)
1.92
PTC rating (W DC)
319
Source last update
2020-04-21
Safety certification
UL 61730, UL 1703
Parallel cell strings
1
Building-integrated PV
N
Maximum-power current Imp (A)
9
Short-circuit current Isc (A)
9.45
Open-circuit voltage Voc (V DC)
47.1
Maximum-power voltage Vmp (V DC)
38.9
Pmax temperature coefficient (%/°C)
-0.43841

Documented compatibility

No specific equipment pairing has been verified for this model.

Shared voltage, a hybrid designation, or the same manufacturer does not establish compatibility. Check the manufacturer’s installation documents for exact model combinations, firmware, and operating conditions.

Registry observation history

Dates show when SolarApprovals observed a status. The first observation is not the original CEC listing date. History begins with our first import.